Answer to Question #235626 in Electrical Engineering for Masande

Question #235626
A 1.5 MVA ,3.3 kV, 40 pole, three-phase star connected asynchronous alternator has
reactance of Xd = 4.01Ω/phase and Xq = 2.88Ω/phase.For a lagging power factor of
0.8 when delivering full load. Calculate a developed power:
1
Expert's answer
2021-09-12T00:30:14-0400

The answer to your question is provided in the image:

Need a fast expert's response?

Submit order

and get a quick answer at the best price

for any assignment or question with DETAILED EXPLANATIONS!

Comments

No comments. Be the first!

Leave a comment

LATEST TUTORIALS
New on Blog
APPROVED BY CLIENTS